Test bench for inductive displacement transducers (LVDT)

The LVDT station manipulates, clamps and connects pilot valves in order to calibrate their differential transformer (LVDT). The test stand ensures a fully automated test sequence including an external robot for test handling. It is operated by the integrated control system. The test cell is monitored to guarantee the highest possible safety. The test report is generated automatically.

Technical data

  • Medium: hydraulic oil SHELL Tellus 15
  • Drive power: 3,7 kW
  • Pressure: max. 250 bar
  • Tank volume: 63 L
  • Filtration