Cylinders production

Cylinder test bench

tilt cylinder

Features

  • Fully automated test sequence
  • Save the test results in the database
  • Automatic generation of a test report
  • Parameterization of the system via the integrated control
  • Functional test of tilt cylinders according to the test procedure
  • Safety-related monitoring of the test cell

Technical “Key-Performance”-Parameters

  • Medium: hydraulic oil HLP 15
  • Pressure: up to 420 bar
  • Power consumption: 110 kW
  • Weight: 14800 kg
  • Dimensions: 6050 x 2650 x 2800 mm

Cylinder test bench

hydraulic cylinders

Features

  • Tests according to DIN EN 1494:2000
  • Removable table element for testing longer test specimens
  • Control with calibration mode for measuring sensors
  • Doors with safety glass according to EN1063
  • Storage of test results in a database and automatic generation of a test report

Technical "key performance" parameters

  • Flow rate: up to 40 l/min
  • Pressure: up to 450 bar
  • Filtration: 18/16/13 according to ISO 4406:1999
  • Hydraulic oil: HLP 32

Cylinder test bench

hydraulic lifting devices

Features

  • Semi-automated test sequence
  • Connection to the customer database for archiving the test reports
  • Automatic generation of a test report
  • Function test of rerailing cylinders
  • Testing according to DIN EN 1494: 2000
  • Safety-related monitoring of the test cell

Technical “Key-Performance”-Parameters

  • Medium: hydraulic oil HLP32
  • Pressure: up to 450 bar
  • Power consumption: 20 kW
  • Filtration
  • Weight: total 10600 kg
  • Dimensions:
    • Test cell: 2300 x 1800 x 3500 mm
    • Power unit: 1400 x 1900 x 2250 mm

Cylinder test bench

hydraulic cylinder multiple tests

Features

  • Multiple tests of hydraulic cylinders (up to 4 cylinders)
  • Automated test sequence
  • Operation via touch panel / barcode scanner (on request via monitor and keyboard)
  • Semi-automated test heads
  • Automated oil refill
  • Storage of the test results in a database and automatic generation of a test report

Technical “Key-Performance”-Parameters

  • Number of HP and LP test circuits each 4 circuits up to 630 bar and 1 circuit up to 1000 bar
  • Tank volume: 2500l
  • Filtration: 18/16/13 acc. ISO 4406
  • Particle Counter
  • Dimensions ca. l x b x h 8000 x 5500 x 5500 mm